新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > caustic soda solution gear flow sensor
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

caustic soda solution gear flow sensor

Date:2017-01-02 source:

  caustic soda solution gear flow sensor  

email: porter@microflowmeter.com  Shanghai JSNMicro Flow Meter CO.,LTD was founded in 2011 by Mr Stone and it was a familycompany which has more than 30 years history. We are specialized in highquality, high accuracym high frequence , temperature and wide measuring rangeflow measuring and detecting equipment. We strictly enforce ISO9001 standard.Our main produsts are: super mirco flow meter,oval gear flow meter ,coriolismass flow meter,electromagnetic flow meter,piston flow meter,spur gear flowmeter,gear pump,gear metering pump. Our micro flow meter can replace Kracht, OVAL,SIKA and OMAGE foreign brands and so on. Our flow meters are mainly used forwater treatment, oil, food, grease industries; chemical,ink, pharmacy, petroleum,cars; glue ,  polyurethaneand electrolyte and additives and other industries.

 caustic soda solution gear flow sensor

caustic soda solution gear flow sensor

At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.

Base deep gear wheel flowmeter on the production of all caliberflowmeters, basically have stock inventory, which in itself shows that thecompany"s funds and sales are good, we dare to do inventory. Hee Oval gear flowmeter has two national inventions, In the process of production qualitycontrol, starting from the beginning of the procurement of raw materials, everyproduction and precision machining links careful examination, each of the Ovalgear flow meter factory must be continuous calibration test. Processinstallation ISO9001 quality management system strictly enforced, the producthas the CE, SGS and other EU certification. Our company has "the qualityof Germany, China"s manufacturing" as the slogan to create a world-classoval gear flow, real automation instrumentation industry Benchmarking business.

gear flow sensor

caustic soda solution gear flow sensor

The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

 caustic soda solution gear flow sensor

caustic soda solution gear flow sensor

Maintechnical data of JSN micro oval Oval gear flow meter

CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"

CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"

CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"

CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"

CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"

CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"

CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"


What are the precautions for the gear flow meter?

1) If the medium temperature is too high, or the pressure is too high, please inform us before purchasing, we can customize it for you.

2) When the pipeline is continuously operated and the flowmeter is to be installed in a horizontal pipeline, a bypass pipeline should be installed to facilitate cleaning and overhaul; when the flowmeter is installed on a vertical pipeline, the flowmeter should be installed on the bypass. In the pipeline, to prevent debris from falling into the instrument. When the fluid flows from bottom to top, the vertical tube in the upper part of the flowmeter should be as short as possible to reduce the precipitation of impurities in the upper piping.